Cable Fault Locator is a precision instrument, easy to use, which provides spontaneous display of the location of break in pair wires and cables.
Cable route locator idefies the underground liad cable path along with its depth
Depth Measurement Accuracy | +/-5%+10 cm |
Spectrum Frequency Range | 10 - 26 000 Hz |
Battery Life | 13 h |
Battery Type | 4 Ni-Mh AA |
Depth | 6 m |
Dimensions | 257x88x685 mm |
Locating of Insulation Resistance Fault | 0 - 100 kOhm |
Trace Location Accuracy | 10 cm |
Weight | 1.9 Kg (with the battery) |
Active Frequency | 26 250 ???? ± 12 ???? |
6562,5 ± 1 Hz | |
2187,5 ± 1 Hz | |
273,5 ± 0,5 Hz | |
Frequency mode "Frendly frequency Hz xxx" | 200-35000 Hz |
Bandwidth Amplitude –3 dB (≤) | |
for frequency 26250 Hz | 150 Hz |
for frequency 6562,5 Hz | 45 Hz |
for frequency 2187,5 Hz | 15 Hz |
for frequency 273,5 Hz | 2,5 Hz |
Working frequencies range of the Signal cur-rent source (preset), Hz | 273,4 ± 0,5 2187,5 ± 1 6562,5 ± 2 26250 ± 3 |
Working frequencies range, Hz | 250 - 35 000 |
Range of the automatic coordination with resis-tance of loading, Ohm | 1 - 500 |
Power output (not less), watt at the resistance of loading 50-500 Ohm: | |
In frequencies range 250 - 10 000 Hz | 10 +/- 1 |
In frequencies range 10 - 20 kHz | 5 +/- 0,5 |
In frequencies range 20 - 30 kHz | 3 +/- 0,5 |
Time of continuous work from the built in accumulator3, hour | 3 |
Time of charging of the built in storage battery (no more), hours | 6 |
Minimum Order Quantity | 2 Piece |
Model | CD950 |
Usage | Industrial |
Pulse Amplitude | 30 V |
Measurement Range | 0-8 km |
Dead Zone | 1 m |
Gain Adjustment Range | 100-300 m/us |
Display | 128x64 lattice LCD |
Power Suppy | 6x5aa batteries or Ni-MH battery |
Dimensions | 225x105x50 mm |
Weight | 0.42 kg (without batteries) |
Usage/Application | TELECOM |
Model Name/Number | VTC 612 |
Brand | VTECH |
Overview
This cable fault locator is designed for ease of use, portable, light weight and easy for carry.
It takes the time domain reflectometer (TDR) for measuring the exact fault location such as the broken line, cross faults, earthing, poor insulation and poor contact of the lead covered cables as well as plastic cables.
As you set proper wave velocity, just press Auto key, you will get the test result within 2 seconds.
It is an effective tool to reduce troubleshooting time, improve work efficiency and reduce labor intensity of line maintenance staff. It also can be used in line projects acceptance and inspection of electrical cables.
Features
1. No test dead zone
2. Fast test speed and accurate test distance
3. Portable and easy to carry
4. Large colorful LCD display;
5. Humanized operation interface;
6. High-energy Li battery, continuous work 10 hours
Specifications
1) Max range: 8 km
2) Highest resolution: 1m
3) Dead Zone: 0 m
4) Power consumption: 1W
5) Weight(kg): 0.42kg
6) Dimension(mm): 200×90×43mm3
7) Working temperature: -15???~+45???
Storage temperature: -20???~+55???
8) USB storage (optional): transmit wave form to U disk, and analyze the wave form on computer.
Supplied complete with:
1) Carry case.
2) Re-chargeable battery and charger/adapter.
3) Test Line
4) User Manual
5) CD (Just for USB function)
6) U-disk (Just for USB function)
Working Frequencies | 200 hz - 35 khz |
Depth | 6 m |
Trace Location Accuracy | 10 cm |
Locating of Insulation Resistance Fault | 0 - 100 kOhm |
Spectrum Frequency Range | 10 - 26 000 Hz |
Battery Life | 13 h |
Dimensions | 257x88x685 mm |
Weight | 1.9 Kg (with the battery) |
Ground at a Distance | 15-20 m aside from the Cable |
Specifications:
Active Frequency | 26 250 Гц ± 12 Гц |
6562,5 ± 1 Hz | |
2187,5 ± 1 Hz | |
273,5 ± 0,5 Hz | |
Frequency mode "Frendly frequency Hz xxx" | 200-35000 Hz |
Bandwidth Amplitude –3 dB (≤) | |
for frequency 26250 Hz | 150 Hz |
for frequency 6562,5 Hz | 45 Hz |
for frequency 2187,5 Hz | 15 Hz |
for frequency 273,5 Hz | 2,5 Hz |
Working frequencies range of the Signal cur-rent source (preset), Hz | 273,4 ± 0,5 2187,5 ± 1 6562,5 ± 2 26250 ± 3 |
Working frequencies range, Hz | 250 - 35 000 |
Range of the automatic coordination with resis-tance of loading, Ohm | 1 - 500 |
Power output (not less), watt at the resistance of loading 50-500 Ohm: | |
In frequencies range 250 - 10 000 Hz | 10 +/- 1 |
In frequencies range 10 - 20 kHz | 5 +/- 0,5 |
In frequencies range 20 - 30 kHz | 3 +/- 0,5 |
Time of continuous work from the built in accumulator3, hour | 3 |
Time of charging of the built in storage battery (no more), hours | 6 |